Raven Cart Automation™ Combine Calibration

  1. Enter the VTClosed A Universal Terminal (formerly Virtual Terminal) is an electronic display or console capable of interfacing with ECUs on an ISOBUS network. Menu and select the Raven Cart Automation™ tab.

  2. Press the Gears button.

  3. Press Combine as the machine type.

  4. Press the Next button.

  5. Enter the width of the combine header.

    Note:  The entire width of the combine header is measured.

  6. Press the Next button.

  7. Enter the Toward / Away Nudge Increment Amount.

    Note:  The maximum allowed configurable nudge distance set is 38 cm [15 in] the default is 15 cm [6 in].

    Note:  The maximum distance that can be nudge away from the combine is 152 cm [60 in]. The maximum distance that can be nudge towards combine is 38 cm [15 in].

  8. Press the Check Mark.

Last Revised: Nov 2023